GradeTDS and samplesTypeMain useMix ratiopolyol/isoOH valuemg KOH/gViscositymPa·s at °CFRDkg/m³MDkg/m³
NGC Rigid 32622Request TDS / samplePURDiscontinuous panel100/120–125300–350250–350 at 25 °C24–2638–40
NGC Rigid 32124Request TDS / samplePIRDiscontinuous panel100/135–145300–350250–350 at 25 °C24–2640–42
NGC Rigid 32320Request TDS / samplePURDiscontinuous panel100/120–125300–350250–325 at 25 °C24–2638–40
NGC Rigid 32360Request TDS / samplePIRDiscontinuous panel100/135–145300–350250–275 at 25 °C24–2640–42
NGC Rigid 38025Request TDS / samplePURContinuous panel100/130–135380–4202,000–2,500 at 25 °C34–3638–40
NGC Rigid 38026Request TDS / samplePIRContinuous panel100/140–145380–4202,000–2,500 at 25 °C36–3840–42
NGC Rigid 32226Request TDS / samplePURAHU panel100/120–125300–350250–350 at 25 °C22–2638–40
NGC Rigid 32023Request TDS / sample—Discontinuous sandwich panelsData on request
NGC Rigid 32123Request TDS / sample—Discontinuous sandwich panelsData on request
NGC Rigid 35023-DIRequest TDS / sample—Discontinuous sandwich panelsData on request
NGC Rigid 35023-ILRequest TDS / sample—Discontinuous sandwich panelsData on request
NGC Rigid 35035Request TDS / sample—B3 discontinuous panelsData on request
NGC Rigid 32135Request TDS / sample—Discontinuous panelsData on request
NGC Rigid 38097Request TDS / sample—Continuous panelsData on request
NGC Rigid 38029CPRequest TDS / sample—Continuous panelsData on request

Spray insulation (7)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoOH valuemg KOH/gViscositymPa·s at °CFRDkg/m³MDkg/m³
NGC Rigid 33545Request TDS / samplePURSpray insulation100/110–120300–350200–250 at 25 °C35–4035–40
NGC Rigid 34245Request TDS / samplePIRSpray insulation100/135–145300–350200–250 at 25 °C40–4540–45
NGC Rigid 33544Request TDS / samplePURSpray insulation100/110–120300–350200–250 at 25 °C35–4035–40
NGC Rigid 34244Request TDS / samplePIRSpray insulation100/135–145300–350200–250 at 25 °C40–4540–45
NGC Rigid 35031BERequest TDS / sample—B2 spray foamData on request
NGC Rigid 35031MARequest TDS / sample—B2 spray foamData on request
NGC Rigid 35031SRequest TDS / sample—Spray foamData on request

Pipe insulation and pipe supports (7)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoOH valuemg KOH/gViscositymPa·s at °CFRDkg/m³MDkg/m³
NGC Rigid 36300Request TDS / samplePURPipe line100/120–125300–350250–350 at 25 °C24–2838–40
NGC Rigid 36500Request TDS / samplePIRPipe line100/135–145300–350250–350 at 25 °C24–2838–40
NGC Rigid 35006Request TDS / samplePURPipe line100/120–125300–350250–350 at 25 °C24–2838–40
NGC Rigid 35060Request TDS / samplePIRPipe line100/135–145300–350250–350 at 25 °C24–2838–40
NGC Rigid 36400Request TDS / samplePURPipe line100/120–125300–350250–350 at 25 °C24–2838–40
NGC Rigid 36040Request TDS / samplePIRPipe line100/135–145300–350250–350 at 25 °C24–2838–40
NGC Rigid 34210Request TDS / samplePURPipe support100/110–120380–400850–1,150 at 25 °C200–300300–400

Appliances, water heaters and thermoware (12)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoOH valuemg KOH/gViscositymPa·s at °CFRDkg/m³MDkg/m³
NGC Rigid 32025RRequest TDS / samplePUDomestic refrigerator100/140–145380–4102,000–3,000 at 25 °C22–2838–40
NGC Rigid 32027RRequest TDS / samplePUDomestic refrigerator100/120–125300–350250–350 at 25 °C24–2635–40
NGC Rigid 32028RRequest TDS / samplePUDomestic refrigerator100/120–125300–350250–350 at 25 °C24–2635–40
NGC Rigid 32032RRequest TDS / samplePUCommercial refrigerator100/140–145380–4102,000–3,000 at 25 °C22–2838–40
NGC Rigid 32033RRequest TDS / samplePUCommercial refrigerator100/120–125300–350250–350 at 25 °C24–2635–40
NGC Rigid 32034RRequest TDS / samplePUCommercial refrigerator100/120–125300–350250–350 at 25 °C24–2635–40
NGC Rigid 32224Request TDS / samplePURWater heater (electric and solar)100/110–120300–350250–350 at 25 °C22–2435–40
NGC Rigid 32021Request TDS / samplePURThermoware100/120–125300–350250–350 at 25 °C22–2436–38
NGC Rigid 32022Request TDS / samplePURThermoware100/120–125300–350250–350 at 25 °C22–2436–38
NGC Rigid 32036Request TDS / sample—Water heater insulationData on request
NGC Rigid 33515BAPRequest TDS / sample—Coolers, freezersData on request
NGC Rigid 32018HFRequest TDS / sample—Solar water heatersData on request

In-situ pouring, block foam and general insulation (15)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoOH valuemg KOH/gViscositymPa·s at °CFRDkg/m³MDkg/m³
NGC Rigid 31705Request TDS / samplePURIn-situ pouring100/125–130300–350250–350 at 25 °C28–3238–40
NGC Rigid 31706Request TDS / samplePIRIn-situ pouring100/135–145300–350250–350 at 25 °C28–3238–40
NGC Rigid 31805Request TDS / samplePURIn-situ pouring100/125–130300–350250–350 at 25 °C28–3238–40
NGC Rigid 31806Request TDS / samplePIRIn-situ pouring100/135–145300–350250–350 at 25 °C28–3238–40
NGC Rigid 32429Request TDS / samplePURBlock foam100/125–130300–350220–350 at 25 °C26–2838–40
NGC Rigid 32332Request TDS / samplePIRBlock foam100/135–145300–350220–350 at 25 °C26–2838–40
NGC Rigid 32729Request TDS / samplePURBlock foam100/125–130300–350220–350 at 25 °C26–2838–40
NGC Rigid 32735Request TDS / samplePIRBlock foam100/135–145300–350220–350 at 25 °C26–2838–40
NGC Rigid 34555Request TDS / samplePURGeneral insulation100/125–130300–350250–350 at 25 °C30–3238–40
NGC Rigid 35545Request TDS / samplePURGeneral insulation100/125–130290–340250–350 at 25 °C30–3238–40
NGC Rigid 35018Request TDS / sample—In-situ pouring and general insulation, B2 grade100/135–145—250–350 at 25 °C48–5260–65
NGC Rigid 33617HFCRequest TDS / sample—In-situ: tanks, hullsData on request
NGC Rigid 34017HFCRequest TDS / sample—In-situ: tanks, hullsData on request
NGC Rigid 35017IRequest TDS / sample—In-situ pouringData on request
NGC Rigid 37517Request TDS / samplePIRPIR in-situ insulationData on request

Moulded parts, packaging and injection grouting (6)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoOH valuemg KOH/gViscositymPa·s at °CFRDkg/m³MDkg/m³
NGC Rigid 34250Request TDS / samplePURWood imitation100/110–120350–400800–1,200 at 25 °C200–350300–400
NGC Rigid 31038Request TDS / samplePURRotomoulded pallet100/120–125300–350250–350 at 25 °C24–2638–40
NGC Rigid 33842Request TDS / samplePURRotomoulded pallet100/120–125300–350250–350 at 25 °C24–2638–40
NGC Rigid 31421Request TDS / samplePUPackaging foam100/100–110250–300800–1,000 at 25 °C12–1618–20
NGC Rigid 35065Request TDS / sample—Injection groutingData on request
NGC Rigid 35965HGRequest TDS / sample—Injection groutingData on request

FRD = free-rise density, MD = moulded (core) density, kg/m³. Mix ratio is polyol blend to isocyanate. Blowing agent per grade: ask us. In Great Britain, HFCs with a GWP of 150 or more are banned in foams, and we won't offer HFC-blown systems.

10 systems

Flexible and moulded foam systems (NGC Flex)

High-resilience (HR) and flame-retardant moulded foam systems for seating, furniture and bedding.

High-resilience (HR) moulded foam (9)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoCore densitykg/m³
NGC Flex 1790Request TDS / sampleHR mouldedAutomotive seats100/70–7542–50
NGC Flex 1791Request TDS / sampleHR mouldedFurniture and cushions100/60–7042–50
NGC Flex 1793Request TDS / sampleHR mouldedMotorcycle, bicycle and tractor seats100/60–7042–50
NGC Flex 1794Request TDS / sampleHR mouldedMattresses100/55–7042–50
NGC Flex 1795Request TDS / sampleHR mouldedStress balls (smile balls)100/45–5036–40
NGC Flex 1792Request TDS / sampleHR mouldedMattresses, general purposeData on request
NGC Flex 1796Request TDS / sampleHR mouldedSport products (smiley balls)Data on request
NGC Flex 1797HDRequest TDS / sampleHR mouldedHigh-density mattresses, sport productsData on request
NGC Flex 1798HDRequest TDS / sampleHR mouldedHigh-density cushions, sport productsData on request

Flame-retardant moulded foam (1)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoOH valuemg KOH/gViscositymPa·s at °CFRDkg/m³MDkg/m³
NGC Flex 1798FRRequest TDS / sampleFR mouldedFlame-retardant moulded foam: railway seats and beds, furniture cushions. Water blown; works with expandable graphite. Iso: NGC Prepol 9848100/32–35 (blended polyol/iso)34–361,200–1,600 at 25 °C45–5590–110
4 systems

Integral skin systems (NGC Skin)

Integral skin foam systems mould a tough skin over a lighter core in one shot.

Integral skin foam (4)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoOH valuemg KOH/gViscositymPa·s at °CFRDkg/m³MDkg/m³Processing
NGC Skin 2763Request TDS / sampleintegral skinChair handles, armrests, bicycle saddles100/40–45156780 at 25 °C110–130190–250Cream 17–23 s, gel 38–48 s, mould 35–45 °C, demould 3–4 min
NGC Skin 2765Request TDS / sampleintegral skinSteering wheels, armrests100/45–55——200–250350–400Cream 10–13 s, gel 27–35 s, mould 40–45 °C, demould 3–4 min
NGC Skin 2763BRequest TDS / sampleintegral skinArmrests, saddles, furniture seatsData on request
NGC Skin 2785Request TDS / sampleintegral skinHigh-density automotive floor matsData on request
1 system

Filter and gasket systems (NGC Seal)

Moulded foam for automotive air filters and gaskets.

Filter and gasket foam (1)

GradeTDS and samplesTypeMain useMix ratiopolyol/isoMDkg/m³ProcessingProperties
NGC Seal 4464Request TDS / samplemoulded filter foamAutomotive air filters and gaskets. Iso: NGC Prepol 96535100/35–40300–350Material 25–35 °CHardness 20–35 Shore A, tensile ≥ 0.7 MPa, elongation ≥ 220 %
On request

Footwear systems (NGC Sole)

PU systems for footwear components. Grade data on request: tell us your part and process and we'll come back with what's available.

Ask about NGC Sole
On request

Cast elastomer systems (NGC Cast)

PU systems for cast elastomer parts. Grade data on request: tell us your part and process and we'll come back with what's available.

Ask about NGC Cast

Typical values, not a specification. The TDS for your order is the agreed specification. Packaging, lead time and REACH status are confirmed with each quotation. Always trial before use.

Before supplying any grade into Great Britain or the EU we confirm its UK REACH or EU REACH position and provide an SDS written for GB CLP or EU CLP. Some grades may not yet be documented for UK or EU supply; ask and we'll tell you plainly.

Talk to Vinay

Tell me your process and the grade you use today. I'll match a grade, send the TDS and SDS, and confirm sample timing in writing.

WhatsApp or phone +44 7818 103874 · Email support@nextgenerationchemical.uk